Home Process & Environmental Products Process 510 Series Gas Analyzers 510 Series Gas Analyzers VIA–510 OverviewSpecifications Overview The 510 series of general–purpose gas analyzers provide continuous monitoring of concentrations of the specific sample gas. The analyzers can be operated from controls on the front panel or by commands from a remote computer. Measurement results are displayed on the front panel and are available to remote data logging systems through an industry–standard interface.
The 510 series can be used for a wide variety of analyses and tests, such as industrial process control and composition analysis, and fixed–source emissions monitoring. Each model is configured using one of four analyzers: the VIA–510 infrared analyzer, the CLA–510 chemi–NOX analyzer, and the MPA–510 O2 analyzer.
A high level of sensitivity is achieved through the use of a dual–beam NDIR, Chemiluminescence, and Magneto–pneumatic analysis methods. The NDIR analyzers use an infrared absorption method which offers superior sensitivity, selectivity, and stability. With the Magnetopneumatic analyzer, high–sensitivity measurements can be realized free of zero drift due to the use of N2 as the operation gas. The Chemiluminescence analyzers use a dryer unit equipped with automatic reseneation, so ambient air can be used as the source of O3. It also provides 7 ranges and a range of 1:100 (0–20⁄50⁄100⁄1000⁄2000ppm), making it easy to handle a wide variety of applications. These highly accurate, high performance analyzers are suitable for process monitoring and control.
Model | Gas | Min. | Max. | High–sensitivity range |
VIA–510 | Carbon Monoxide (CO) | 0–100ppm | 0–100% | 0–50ppm |
VIA–510 | Carbon Dioxide (CO2) | 0–100ppm | 0–100% | 0–50ppm |
VIA–510 | Sulfur Dioxide (SO2) | 0–100ppm | 0–100% | 0–50ppm |
VIA–510 | Methane (CH4) | 0–100ppm | 0–100% | 0–50ppm |
VIA–510 | Nitrous Oxide (N2O) | 0–100ppm | 0–100% | 0–50ppm |
MPA–510 | Oxygen (O2) | 0–5% | 0–100% | 0–1% |
CLA–510 | Nitric Oxide (NO) | 0–100ppm | 0–5000ppm | 0–20ppm |
Configuration | Desk top or 19" panel mount |
Ambient conditions | Temperature: 0 to 40 °C Humidity: 90% RH or less |
Power | 100 ⁄ 115 ⁄ 220 V DC, 0 – 10 V DC, 0 – 16 mA or 4 – 20mA DC, isolated |
Output signal | 0 – 1 V DC, 0 – 10 V DC, 0 – 16 or 4 – 20mA DC, isolated |
Display | LED digital display (effective 4 digits.) |
Dimensions | 430 (W) x 132 (H) x 550 (D) mm 16.9 (W) x 5.2 (H) x 21.7 (D) in |
Sample gas requirements | Dust: No Mist: Completely removed Pressure: More than 50 mm H2O Temperature: Ambient temperature Moisture: 5°C saturation or below Flow rate: 500mL / min Exhaust gas: Discharged at ambient pressure |
Measureing method | NDIR |
Repeatability | ±0.5% F.S. (±1.0% F.S. for high–sensitivity range) |
Drift | ±1.0% F.S. per day (±2.0% F.S. per day for high–sensitivity range) |
Response time | 10 sec. (electrical) |
Operation gas | Not needed |
Operation gas | Not needed |
Calibration gas | Zero: N2 or Air, Span: Span gas |
Mass. | 15kg, 33 lb |
Measureing method | Magnetopneumatic |
Repeatability | ±0.5% F.S. (±1.0% F.S. for high–sensitivity range) |
Drift | ±1.0% F.S. per day (±2.0% F.S. per day for high–sensitivity range) |
Response time | 10 sec. (electrical) |
Operation gas | N2, Flow rate: 6 mL⁄min. |
Calibration gas | Zero: N2, Span: Span gas or Air |
Mass. | 15kg, 33 lb |
Measureing method | Chemiluminescence |
Repeatability | ±0.5% F.S. (±1.0% F.S. for high–sensitivity range) |
Drift | ±1.0% F.S. per day (±2.0% F.S. per day for high–sensitivity range) |
Response time | 10 sec. (electrical) |
Operation gas | Not needed (ambient air used) |
Calibration gas | Zero: N2 or Air, Span: Span gas |
Mass. | 20kg, 44 lb |
For more details please contact us here or visit HORIBA Process and Environmental